Monday, 20 November 2017 06:31 Written by 
Rate this item
(0 votes)

TTRM 101

TTRM 101

SCOPE introduces state of the art precision single phase Transformer Turns Ratio Meter (TTRM ) designed for field testing as well as factory testing of power transformers, instrument transformers and distribution transformers of all types. TTRM 101 measures only turns ratio where as TTRM 102 along with turns ratio, measures ratio deviation, phase angle deviation, magnetizing current and detects tap-position of single phase transformer in charged switchyard condition. The range of AC voltage selection offers high accuracy in measurement.Both the instrument have in-built TFT display with touch screen and thermal printer. The user friendly, simple instrument makes the testing more easy. With the touch keypad it is possible to enter required DUT information.The ratio results are displayed with % error. Internal non-volatile memory gives the provision of storing test results.Further data can be downloaded to PC or copied to memory stick through USB port provided.

The C-Trans-software, gives the flexibility to download the stored results to PC and do the further analysis and report generation.

Features

  • Different voltage ranges provided for more accurate results
  • 5.7” TFT display with touch screen and simple menus to operate TTRM
  • Facility to configure transformer ID and details
  • Automatic OLTC operation for tap change
  • Date and time stamping to results
  • In-build memory to store the test results
  • Thermal printer to take quick print out for record
  • Ethernet port for PC interface to transfer records to PC Software
  • Mass storage device (USB 2.0) interface for copying records in pen drive
  • Lightweight, portable instrument household in rugged moulded case

 

Specifications

  Parameter Test Voltage      Range     Resolution Accuracy
1
                 
Ratio 10 V 0.8000 – 9.9999 0.0001

0.05 %

10.000 – 99.999 0.001

0.05 %

100.00 – 999.99 0.01 0.05 %
1000.0 – 1500.0 0.1 0.05 %
1500.1 – 2000.0 0.1 0.1 %
2000.1 – 4000.0 0.1 0.2 %
40 V 0.8000 – 9.9999 0.0001 0.05 %
10.000 – 99.999 0.001 0.05 %
100.00 – 999.99 0.01 0.05 %
1000.0 – 4000.0 0.1 0.05 %
4000.1 – 9999.9 0.1 0.25 %
10000 - 13000 1 0.25 %
100 V 0.8000 – 9.9999 0.0001 0.03 %
10.000 – 99.999 0.001 0.03 %
100.00 – 999.99 0.01 0.05 %
1000.0 – 4000.0 0.1 0.05 %
4000.1 – 9999.9 0.1 0.15 %
10000 – 13000 1 0.15 %
13001 - 20000 1 0.20 %
2   

Excitation Current

(Only in TTRM 102)

10 V 2000 mA 0.1 mA ± 1 mA
40 V 500 mA 0.1 mA ± 1 mA
100 V 200 mA 0.1 mA ± 1 mA
 3  Phase Deviation

(Only in TTRM 102)

10V / 40V / 100 V

± 180 Degree 0.01 Degree ± 0.05 Degree

 

Parameters TTRM 101
No of channels single HV channel and single LV channel
Test Voltages 10V, 40V and 100V AC selectable voltages
Measurements Ratio, Ratio error
OLTC Control Raise and Lower control to operate OLTC
Test Results Display (TFT) display, Thermal Printer.
Test Leads Suitable to test EHV Transformers
Printer Inbuilt Thermal Printer
Paper Thermal, 58 mm wide roll form
Memory Inbuilt memory, can store 50000 records, with date and time stamping. USB port to copy record in pen drive
Power (110V ± 15%) / (60Hz ± 10%) OR (230V ± 15%) / (50Hz ± 10%), 75VA..
Communication Port Ethernet port.
Housing Fitted in moulded case
Environment 0: -20°C to 55°C 95%RH (non-condensing) Electrical noise normally found in charged EHV switchyards
Dimensions 435 X 315X 175 mm. (Max.)
Weight 10 Kg Approx
Read 16222 times Last modified on Friday, 18 February 2022 11:58
More in this category: « MagD TTRM 301 »