TI330+ is with a cooled detector(T2SL, NETD<25mK) to detect gas leaks and pinpoint the gas leaks location accurately, also offers temperature measurement. It is a multifunctional device for gas leakage detection and thermography applications.

TI330+ provide safe & efficient inspection at long distance without shutting systems down, scans large areas & numerous objects rapidly, sees into areas that are difficult to reach with contact measurement tools and enhances predictive maintenance at the same time. It is an ideal device for chemical/petrochemical application such as offshore platforms, oil refineries and natural gas processing plants

Features

      • Cooled T2SL detector, sensitivity ≤0.025℃, pinpoint gas leaks location quickly
      • Dual-application: Gas leakage detection and thermograph application
      • Temperature range: -20℃~+350℃
      • Inspection without interrupting the process
      • Interchangeable lenses available
      • Built-in 5.0 MP digital camera
      • Folding and 270°rotatable display

Specifications

 

Parameters  TI 330+
Detector Data
Type Cooled FPA, Type II Super Lattice(T2SL)
IR resolution 320 x 256
Pixel Pitch  30μm 
Spectral range

3.1~3.5μm

NETD/Sensitivity 25mK
VOC gas sensitivity ≤0.001ml/s
Lens
FOV/Focal distance   10°×7.5°/55mm
Minimum imaging distance 2m
IFOV 0.55mrad
Focus Manual
Image Performance
Display 5”,color LCD, 800×480 pixels
Built-in visible light camera 5 megapixel CMOS, autofocus, 1 LED fill light
Frequency 50Hz
Digital zoom 1X~8X continuous
Colour palettes 12 palettes(including iron, rainbow, white-hot and black hot etc.)
Contrast/brightness Auto/Manual
Measurement
Temperature range -20℃~+350℃
Temperature accuracy  ±2℃/±2%(reading)
Spotmeter 10 adjustable spots
Line profile Vertical/Horizontal
Area 5 adjustable boxes with max./min./avg temperature value
Image Storage
Storage  8G SD card(can be extended to 32G)
Video output Card reader, USB, WiFi 
IR image format JPEG, 14-bit measurement data image included
Video storage High definition video stored in SD card(MPEG4/H.264 format), recording time up to 1 hour for per video
Voice annotation 40s voice record, stored with per image
Periodic image storage 10s to 24h
Power System
Battery type Rechargeable li-ion battery
Charging system In-camera, AC adapter, car charger
Laser Point Grade/Type Class 2,1mW/635nmRed
Operation temperature range -15℃ to +40℃
Storage temperature range -20℃ to +50℃
Humidity  ≤95%(Non-condense)
Size & Weight 308mm×142mm×166mm, ≤2.5kg(with standard lens)
Main Gas Detection VOC, benzene

TD100 is an innovative NDT - Non-Destructive Testing equipment, which detects, pinpoints and documents flash-arc corona and arcing partial discharge camera. Being with high sensitivity, it is a power tool to detect UV emission in full daylight with high signals from faraway and nearby sources.

TD100 is an ideal predictive maintenance device for overhead transmission lines and high voltage substations. It is widely used in Transmission line inspection, electrical utilities, HV research institutes, HV Electrical component inspection, HV panel inspection, service providers, laboratories and so on

Features

      • High sensitivity up to 3.0 × 10-18watt / cm2
      • Noise interference is small, using an all-day blind detector
      • Accurate superposition and positioning of the whole area of ultraviolet and visible light
      • Hand-held inspection, easy to complete the inspection
      • Synchronous focusing of ultraviolet and visible light
      • SD card online upgrade function
      • High integration and low power consumption
      • Professional report analysis software, more conducive to on-site situation analysis
      • Small size, light weight, easy to operate

Specifications

 

Parameters  TD 100
Minimum UV sensitivity 3.0×10-18watt/cm2
Minimum discharge detection 5pC@10m
Radio voltage detector sensitivity 3.6dBμV@1MHz
Spectral range  240-280nm 
Field of View (FOV)

6.4° x 4.8°

Focus Auto/Manual(Follow visible light)
Zoom 2x
Detector life span No Degradation
LCD screen   Visible 5” LCD screen under sunlight, 800×480
Image modes Display only ultraviolet light image/display only visible light image/combination of visible light and ultraviolet light
UV/Visible overlay accuracy  ≤1mrad
Status Indicators Battery power, gain, photons, date, focusing mode, stacking module, GPS
User configuration settings Corona colour (White, Red, Green, Yellow, Purple), Time, Sleep Mode, Alarm threshold
Image format JPG
Video format AVI
Media download Via Card Reader, USB
Storage capacity 1000+ images or >1 hr video/1GB
External power DC: 9V~12V
Battery type Lithium battery (rechargeable)
Operation runtime 4h continuous (normal temperature)
Power Consumption 10W
Operation   with single phase 230 V ±10% or battery 
Mains adaptor AC:110V~240V or DC: 50Hz~60Hz/9V 3.8A
Operating temperature -10°C  to +50°C
Storage temperature  -25°C to +60°C
Humidity  90% non-condensing
Encapsulation  IP 54 
Size & Weight  290mm×136mm×87mm , 1.39 kg 

The new generation CFL PP3+ Cable Fault Pin Pointer cum route tracer from SCOPE is the ultimate solution for locating of underground cable faults in minimum time by tracing cable route. It uses an advanced technology which helps even an unskilled operator to locate the fault accurately.

For pinpointing it is used along-with CFL SG Series Surge Generators and for route tracing it is used along-with CFL AG Series Audio Frequency Generators. Advanced technology with features like time-lapse measurement, makes it a tool that can tackle complicated faults easily.

Features

  • Compact, Lightweight and Rugged
  • Operation via User Friendly 5.7” colour Touchscreen Display
  • Universal Receiver used for Route Tracing and Pinpointing
  • Backlit facility with intensity control for ease of viewing in direct sunlight
  • Simultaneous display of Magnetic and Acoustic waveforms
  • Time-lapse / delay measurement facility
  • Automatic Fault Point Indication using Coincidence Method
  • Noise suppression filters to eliminate external influences
  • Mute function for headphones to disable noise while moving
  • Route guidance (Compass) feature during Pinpointing
  • Detection of live loaded cable (50Hz frequency)
  • Specially designed lightweight, neck carrying case ensuring minimum strain to the operator
  • Inbuilt Rechargeable Battery
  • Water-resistant and dustproof design
  • Supplied in an IP67 Class Molded Case

Specifications

Parameters  CFL PP3+
Channels Acoustic and Magnetic (Dual Channel)
Operating Principle Coincidence Method
Gain Up to 120dB adjustable for Acoustic & Magnetic
Volume limitation warning 84dB
Headphone Jack  3.5mm
O/P impedance of headphone 8Ω to 72Ω (32Ω is recommended)
Acoustic Channel Bandwidth 70Hz to 3000Hz with automatic filtering
Magnetic Channel Bandwidth 120Hz to 20kHz Auto-tuned
Battery 11.1V Lithium-Ion Rechargeable
Charger Input 90V to 270V AC, 50/60 Hz, Single Phase
Operating Time 10 Hours Min (Approx)
Display  5.7'', 320 x 240 pixel, Colour, TFT Touch Screen
Environmental -20°C to 55°C, 95% RH (Non-Condensing)
Dimensions of Receiver 231mm x 90mm x 135mm
Weight of Receiver 1.4 kg

After excavation, sometimes it is confusing to identify the right cable from a bunch of cables. Cable Identification is very important for the safety of field personnel – Cutting a wrong cable can be fatal. So, we require a Cable Identification System to identify the wanted cable.

Cable Identification is the most critical and safety-related sequence during all the procedure of Cable Fault Location. The correct identification of a cable out of a bundle of cables, where most of them can be in service, has to be carried out not only carefully, but also by means of an instrument widely eliminating the possibility of human error or misinterpretation.

The Cable Identification System, CFL CIS from SCOPE is the ultimate solution for identifying wanted (dead) cable from a bunch of cables in a trench, pit or cable rack. The SCOPE’s Cable Identification System, CFL CIS is designed to fulfil these most important safety aspects

Features

  • Compact, Lightweight and Rugged
  • User Friendly LED Indication for Right & Wrong Cable Identification from multiple cables
  • Thin and Flexible Current Clamp for easy insertion between closely mounted Cables
  • 10 Stage amplifier setting for better signal identification
  • Transmitter operation through Mains as well as In-built rechargeable battery
  • Transmitter housed in IP67 class moulded case
  • Neck Belt arrangement for easy carrying of Receiver

Specifications

Parameters  CIS 
Pulse Amplitude Selectable between 100A (55V) / 60A (36V)
Pulse Sequence 10 or 20 or 30 pulses/min, User configurable
Pulse Modulation  Alternative pulse at 1s and 2.5s
Pulse Width 72ms
Display 4 line x 20 characters backlit LCD
Power 90V to 265V AC, 50/60Hz or In-built 11.1V Lithium Ion Rechargeable battery
Battery Operating time 6 Hours Min.
Environmental  -20°C to +55°C, 95% RH (Non-Condensing)
Dimensions & Weight 339mm x 295mm x 152mm, 6 Kg approx

 

Parameters  CIS-R
Display Type LED Scale
Flexible Clamp 150mm Diameter
Sensitivity 100% at 31Ω loop resistance
Amplifier 10 stage gain setting
Power 11.1V Lithium-Ion Rechargeable Battery 
Operating Time 8 Hours Min
Environmental  -20°C to +55°C, 95% RH (Non-Condensing)
Dimensions & Weight 210mm x 124mm x 51mm, 0.7 Kg approx

 

Surge Generator is the backbone of underground cable fault locator test systems. Surge Generator is used with a Prelocator for fault distance measurement and also used with a PinPointer for pinpointing the fault spot.

SCOPE offers CFL SG Series Surge Generators up to 32kV and 2000 Joules. They are compact, rugged, user friendly and have all safety features in place. They are the ideal choice for fault location on all type of power cables. It can also be mounted in a cable test van for quick fault location if one wants to opt for optional van mounted configuration.

For prelocation it is used in ICM (Impulse Current Method) and SIM (Secondary Impulse Method) / MIM /ARC modes. In this modes, one also needs to use SIM Filter for stabilising the arc at fault. For pinpointing it is used as Thumper to create magnetic as well as acoustic signal across the fault, which is sensed by Pin Pointer. 

 

Features

  • Compact, Lightweight and housed in a rugged aluminium case
  • Available with 16kV and 32kV Models with energy options such as 500J, 1000J, 1500J & 2000J
  • Ideal choice for fault location on all type of power cables
  • Backbone of Cable Fault Locator System
  • Generates short duration high voltage surge for fault break down
  • Used to determine the fault distance in conjunction with Prelocator unit
  • Repetitive surges applied for pinpointing the exact fault location in conjunction Pinpointing set
  • Supports SIM/ARM/MIM method for locating High resistance and flashing faults along with Prelocator and SIM Filter
  • Available with optional modes such as DC Hipot, Burn Down and Sheath Fault Locator Mode

Specifications

Parameters  CFL SG1610 / SG 1620 CFL SG3210/SG3215/SG3220
Output Voltage Range   0- 4, 0-8, 0-16kV 0-8, 0-16, 0-32kV
Output Energy 1000J /2000J 1000J / 1500J /2000J
Impulse Period Sequence Single Impulse / 3S / 6S / 9S or other as desired
Measurement Mode Supported ICM (Impulse Current Method), SIM (Secondary Impulse Method) / MIM / ARC
Ouput Indiaction  Moving Coil Meters
Power  230V AC ±10%, 50Hz
Housing Elegant, rugged aluminium housing with trolley mounting
Dimension 484 x 360 x 580 mm 700 X 700 X 880 mm
Weight  65 kg / 70 kg 95 kg / 105 kg / 115 kg

Optional 'DC HiPOT' Mode

Voltage  0-16kV 0-32kV
Current  up to 12mA up to 24mA

Optional 'Burn Down' Mode 

Voltage  0- 4, 0-8, 0-16kV 0-8, 0-16, 0-32kV
Current  0-90, 0-60, 0-30mA in resp ranges 0-240, 0-120, 0-60mA in resp ranges

Optional 'Sheath Fault Locator' Mode

Voltage 0-8kV
Current  0-60mA 0-240mA
Test Timing Interval Single Impulse / 3S / 6S / 9S or other as desired

 

The new generation CFL PL3+ Cable Fault Pre-locator from SCOPE is the ultimate solution for locating underground cable faults in minimum time. It uses advanced technology for fault distance measurement which helps even an unskilled operator to locate the fault accurately up to 128 km.

CFL PL3+ portable Prelocator is used for identification of fault types in underground cables and the distance of fault. These products are designed to find out various types of faults in the cable such as Open Circuit, Short Circuit, Splice in Cable, High Resistance, Moisture Ingress, etc. Various modes of operation combined with advanced features offer the user the most effective solution for the job.

Features

  • Compact, Lightweight and Rugged
  • User-friendly operation
  • Wide measurement range up to 128km
  • Highest measurement accuracy up to 0.01%
  • A high-speed sampling of 800MHz
  • Multiple waveform comparison with Subtraction mode to show waveform differences
  • Zoom function for detailed analysis of the waveform
  • Asynchronous interference & noise suppression
  • Adjustable Gain and Balance
  • Inbuilt Cable Library for easy setup and testing
  • Inbuilt memory to store 300 waveforms with USB connectivity
  • Equipped with 3 TDR channels for analysing 3 phase cable in single connections
  • High resolution 5.7” colour TFT display
  • Mains, as well as Inbuilt Rechargeable Battery, operated
  • Housed in IP67 class moulded case

Specifications

Parameters  CFL PL3+
Modes Of Operations

TDR: Time Domain Reflectometry / Low Voltage Pulse-echo

SIM / MIM / ARC : Secondary Impulse / Arc Reflection/Multiple Impulse

ICM / ICE: Impulse Current

Voltage Decay

Sampling  Rate  800MHz
Measurement Range  Up to 128Km
Measurement Accuracy  0.01% to 0.2%
Resolution  0.01m
Pulse Amplitude (OCV) 10V and 45V selectable
Pulse Width 10nS to 100μS
Output Impedance 25Ω to 600Ω
Velocity of Propagation (VoP)/Propagation Factor (PF) Settings    Parameters  VoP% PF  V/2
From  33.3% 3.000  50m/μS
To 99.9% 1.000 150m/μS
STEP 0.1% 0.001 0.1m/μS
Memory  300 Waveforms
Connectivity USB, Direct Download to Pen Drive 
Cable Library >100 Settings
Display 5.7" Colour TFT
Battery  Rechargeable Lithium-Ion, Suitable for 6-hour operation
Charger Input Supply 90V to 264V AC, 47 to 63 Hz, Single Phase
Environmental -10°C to +50°C, up to 95% RH (Non-Condensing)
Dimension 270mm x 240mm x 120mm
Weight  2.5 Kg

The new generation CFL PL2+ Cable Fault Prelocator from SCOPE is the ultimate solution for locating underground cable faults in minimum time. It uses advanced technology for fault distance measurement which helps even an unskilled operator to locate the fault accurately up to 50 km.

CFL PL2+ portable Prelocator is used for identification of fault types in underground cables and the distance of fault. These products are designed to find out various types of faults in the cable such as Open Circuit, Short Circuit, Splice in Cable, High Resistance, Moisture Ingress, etc. Various modes of operation combined with advanced features offer the user the most effective solution for the job

Features

  • Compact, Lightweight and Rugged
  • User-friendly operation
  • Wide measurement range up to 50km
  • Highest measurement accuracy up to 0.04%
  • A high-speed sampling of 100MHz
  • Multiple waveform comparison with Subtraction mode to show waveform differences
  • Zoom function for a detailed review of the waveform
  • Asynchronous interference & noise suppression
  • Adjustable Gain and Balance
  • Inbuilt Cable Library for easy setup and testing
  • Inbuilt memory to store 100 waveforms
  • RS-232 port for communication
  • High resolution 5.7” Monochrome LCD display
  • Mains, as well as Inbuilt Rechargeable Battery, operated
  • Housed in IP67 class moulded case

Specifications

Parameters  CFL PL2+
Modes Of Operations

TDR: Time Domain Reflectometry / Low Voltage Pulse-echo

SIM / MIM / ARC : Secondary Impulse / Arc Reflection/Multiple Impulse

Sampling  Rate  100MHz
Measurement Range  Up to 50 Km
Measurement Accuracy  0.04% to 0.4%
Resolution  0.01m
Pulse Amplitude (OCV) 10V
Pulse Width 10nS to 100μS
Output Impedance 25Ω to 600Ω (Default 75Ω)
Velocity of Propagation (VoP)/Propagation Factor (PF) Settings   Parameters  PF  V/2
From  1.000  50m/μS
To 3.000 150m/μS
Memory  100 Waveforms
Connectivity RS-232
Cable Library >100 Settings
Display 5.7" Monochrome, LCD
Battery  Rechargeable Lithium-Ion, Suitable for 8-hour operation
Charger Input Supply 90V to 264V AC, 47 to 63 Hz, Single Phase
Environmental -10°C to +50°C, up to 95% RH (Non-Condensing)
Dimension 270mm x 240mm x 120mm
Weight  2.5 Kg

The new generation CFL PL4+ Cable Fault Pre-locator from SCOPE is the ultimate solution for locating underground cable faults in minimum time. It uses advanced technology for fault distance measurement which helps even an unskilled operator to locate the fault accurately up to 256 km.

CFL PL4+ portable Prelocator is used for identification of fault types in underground cables and the distance of fault. These products are designed to find out various types of faults in the cable such as Open Circuit, Short Circuit, Splice in Cable, High Resistance, Moisture Ingress, etc. Various modes of operation combined with advanced features offer the user the most effective solution for the job

Features

  • Compact, Lightweight and Rugged
  • User-friendly operation
  • Wide measurement range up to 256km
  • Highest measurement accuracy up to 0.025%
  • A high-speed sampling of 800MHz
  • Multiple waveform comparison with Subtraction mode to show waveform differences
  • Zoom function for detailed analysis of the waveform
  • Asynchronous interference & noise suppression
  • Adjustable Gain and Balance
  • Inbuilt Cable Library for easy setup and testing
  • Inbuilt memory to store 300 waveforms with USB connectivity
  • High resolution 10.4” colour TFT display
  • “Screenshot” function with image saving in JPG
  • Mains, as well as Inbuilt Rechargeable Battery, operated
  • Housed in IP67 class moulded case

Specifications

Parameters  CFL PL4+
Modes Of Operations

TDR: Time Domain Reflectometry / Low Voltage Pulse-echo

SIM / MIM / ARC : Secondary Impulse / Arc Reflection/Multiple Impulse

ICM / ICE: Impulse Current

Voltage Decay

Sampling  Rate  800MHz
Measurement Range  Up to 256 Km
Measurement Accuracy  0.025% to 0.2%
Resolution  0.01m
Pulse Amplitude (OCV) 18V and 86V selectable
Pulse Width 10nS to 100μS
Output Impedance 25Ω to 600Ω (Default 75Ω)
Velocity of Propagation (VoP)/Propagation Factor (PF) Settings    Parameters  VoP% PF  V/2
From  33.3% 3.000  50m/μS
To 99.9% 1.000 150m/μS
STEP 0.1% 0.001 0.1m/μS
Memory  300 Waveforms
Connectivity USB, Direct Download to Pen Drive 
Cable Library >100 Settings
Display 10.4" Colour TFT
Battery  Rechargeable Lithium-Ion, Suitable for 6-hour operation
Charger Input Supply 90V to 264V AC, 47 to 63 Hz, Single Phase
Environmental -10°C to +50°C, up to 95% RH (Non-Condensing)
Dimension 339mm x 295mm x 152mm
Weight  3.7 Kg

The TM25R grounding resistance meter for high frequency has been developed  to ensure Testing of the power transmission towers grounding (G) without interruption of the power. This is the appropriate tool for a fast, safe and reliable grounding resistance measurement in each tower of a working line transmission, without disconnecting the ground wire.

The TM25R has a Bluetooth interface that allows remote control of it through a tablet with BlueLogg software. With it you can save the photos of the towers and the GPS coordinates of each. It also allows you to record voice comments for each measurement. This equipment is powered with its universal charger, from a built-in rechargeable battery. It is a strong equipment, easy to carry, resistant to the hard weather and geographical features of the tropical and high-mountain regions, that is why it is described as an excellent product for field works under the most severe environmental conditions.

 

Features

  • Intended for measurement of earth resistance of electricity pylons
  • Minimizes the influence of adjacent pylons, connected by the guard cable
  • Operation frequency: 25 kHz
  • Resistance reading: up to 300 Ω
  • Automatic current injection
  • Built-in memory and printer
  • Rechargeable battery

Specifications

Specifications    TM25r
Measurement ranges

0 - 300 Ω

Accuracy

± 2.5 % of reading ± 1 digit

Operating Frequency 

25KHz

Test Current 20mA automatic
Interface 

USB & Bluetooth 

Battery charger Internal or external rechargeable battery, 12 V. Internal battery autonomy: at least 2 hours.
Environment 

 -5 °C to 50 °C. (Operating)

-15 °C to 65 °C (Storage) 

Up to 95% RH (non condensing)

Weight 

4.9 Kg (Approx)

Dimension

340 x 295 x 152 mm

The EM-4058 earth tester is a digital, microprocessor controlled instrument that allows to measure the earth resistance and ground resistivity (using Wenner´s method), as well as to detect parasitic voltages present in the ground. This instrument is suitable to measure earth systems in power substations, industries, distribution networks, etc., according to IEC 61557-5.

In order to conveniently test the earth system, EM4058 allows to perform measurements using the test current which frequency may be operator-selected (270 Hz, 570 Hz, 870 Hz, 1170 Hz or 1470 Hz). On one hand, the lowest frequency will allow to analyze the earth system behavior related to fault currents of industrial frequency, while on the other hand, the measurement performed with the highest frequency will best show the behavior in connection with electrical currents caused by lightning and will offer a very high immunity related to interference voltages that are usually present in soils, specially near substations.

The instrument has four ranges that are automatically selected, covering measurements from 0.01 Ω up to 20 kΩ, which allows to obtain very accurate measurements for any kind of soils. During ground resistivity measurement, the operator may indicate the distance between spikes in order for the equipment to apply Wenner's formula and to show the resistivity value directly.

Features

  • Earth resistance measurement
  • Ground resistivity (Wenner's method)
  • High spurious voltage rejection
  • Spurious voltage measurement
  • Measure with multiples frequencies (270 Hz, 570 Hz, 870 Hz, 1170 Hz, 1470 Hz)
  • 0.01 Ω resolution
  • Up to 20 kΩ resistance range
  • Remote control through an Android App
  • Auto-range
  • Built-in memory
  • Built-in printer
  • USB interface

Specifications

Specifications   
Measurement ranges

Resistances: 0-20 Ω; 0-200 Ω; 0-2,000 Ω; 0-20 kΩ (Auto-ranging)

Resistivity :  0- 50 kΩm (auto ranging)

Voltage: 0-60 V~

Accuracy

Resistance & Resistivity measurements:

R ≤ 2 kΩ: ± (2% of the measured value ± 2 digits).
R > 2 kΩ: ± (5% of the measured value ± 2 digits).

Voltage measurements:

± (2% of the measured value + 1% of end of scale value).

Reading resolution

0.01 Ω in the resistance measurement;

0.01 Ωm in the resistivity measurement;

0.1 V in the voltage measurement.

Output Current The short-circuit current is limited to less than 20.0 mARMS (according the IEC 61557-5 - 4.5).
Operation Frequency

270 Hz (resistance or resistivity measurement)

570 Hz, 870 Hz, 1170 Hz or 1470 Hz (resistance measurement)

Max. variation: ± 1 Hz (both cases).

Battery charger A smart, microprocessor controlled, circuit adjusts the battery charge to the optimised parameters in order to ensure the maximum service life. It is supplied by means of an external AC adapter (provided with the equipment) or from a 12 V car battery.