Auto-recognition of the tripping conditions (contact or voltage) |
| • |
Digital monitoring device : measuring and display of times |
| • |
Multifunction measuring device : Maximum, Minimum, timer and recloser |
| • |
CMV01 : 1 START input and 1 STOP input |
| • |
CMV03 : 1 START input and 3 STOP inputs |
|
| Frequency Meter and Phase Shifter, Three Phase : FPM03 |
| • |
Digital frequency meter and phase shifter |
| • |
Maximum voltage : 600Vac |
| • |
Multifunction monitoring device |
| • |
Measuring and display of frequencies, phases, and three-phase voltages |
| • |
Phases arrangement |
|
| Current/Voltage Calibrator : TESTQUAL |
| • |
Recalibration and test device for qualimeters |
| • |
One fixed voltage generator 220Vac |
| • |
One fixed voltage generator 220Vac |
| • |
Electronic regulation et protection |
| • |
Digital display : 4½ digits to measure voltages up to 230V, and currents up to 5A |
|
| Laboratory SDC Source |
| • |
1 kW in a 1U case, 10 kW in a 10U case |
| • |
88 to 264 Vac for 1000 W |
| • |
230 Vac for 2000-3000 W |
| • |
3 x 400 Vac for 4, 6, 8 and 10 kW |
|
| Direct Current Generator : GCC |
| • |
Direct current generator up to 20mA, voltage : 0/10V |
| • |
10 channels per device |
| • |
Settings by means of potentiometers |
| • |
Settings by means of potentiometers |
| • |
Digital display : 3½ digits |
| • |
2 models: rack or box-packed |
|
| Continuous power generator : AC |
| • |
Continuous voltage or current generator |
| • |
Digital display |
| • |
Overload protection |
|
|
| Fictitious Circuit Breaker : DF40/140 |
| • |
Easy simulation of circuit-breaker's automatism |
| • |
Three phase |
| • |
Single or triple-phase trigger |
| • |
Position of the circuit-breaker's pins (open, closed, discordance) |
|
|
| Liquid Level Detector: DN |
| • |
Level detection of conductible and neutral liquids (min, max) |
| • |
Possible actions: warn a control center, or activate a pump |
| • |
DN3/12 : 3 pins for the detection of level with hysteresis. |
| • |
DN2/12 : 2 pins for simple detection. |
|
|
| DC Voltage Power Supply Unit ACM500/1000/3000 |
| • |
2 Voltage ranges |
| • |
1 rectified voltage up to 127Vdc 4A/48Vdc 10A (500W) |
| • |
1 rectified voltage up to 127Vdc 8A/48Vdc 20A (1000W) |
| • |
1 rectified voltage up to 127Vdc 24A/48Vdc 61A (3000W) |
|
|
| Voltage/Frequency Generator GBF50 |
| • |
2 ranges selected by the MICROPILOT |
| • |
0 to 20 V (permanent) Max output 2.5A |
| • |
0 to 240 V (permanent) Max output 0.2A |
| • |
Adjustable by key (0.1V) |
| • |
Frequency: fixed 50Hz - variable 40 to 65 Hz by 0.01Hz step |