Others >>   CT-PT Measurement  
CT/PT testing

Testing Methods are set by national and international standards. The relevant standards subdivide the instrument transformers into classes, for which the amplitude and phase errors are fixed.
The amplitude errors are defined by the relative deviation of the measured amplitudes of the current- or voltage vectors from the nominal values. The phase error is the phase angle of the output minus the phase angle of the input, for a sinusoidal input and output at a fixed frequency. As well known, phase angles will contribute to the measured values of power and thus also the energy. To verify both types of errors, reference standards are necessary, the measuring uncertainty of which is much smaller than those of the devices to be tested

Products:
Automatic Current and Potential Transformer Test Set Low Voltage Unit for Capacitive Voltage Divider Standard Current Transformer Burden
Series W ED-00CR CT-N5K0
For accuracy testing of instrument transformers
Current comparator principle
Matches different ratios of test object and standard transformer in a wide range
Display of the results in all accepted dimensions
Fully automatic
Remote control and data transfer via built-in RS232 interface
Highest accuracy of 10ppm for ratio and phase
This instrument together with a compressed gas standard capacitor replaces inductive standard potential transformers
Broad range of division ratios: 5 digit resolution
Remote control and data transfer via built-in RS232 interface
Highest accuracy of 10ppm for ratio and phase
Covers nominal currents from 5 A up to 5 kA
Operation from 1 up to 200% of nominal current
Burden (artificial load) for voltage and current transformers
High precision by compensating uncertainties of the passive burden elements electronically
Wide range of rated voltages, currents and powers
According IEC 60044 and ANSI/IEEE C57.13
Any burden value up to 200 VA
Add on burdens up to 1'000 VA (option)